  • It’s also the way they make cheap LED headlights. The reflectors that direct the beam of light in your headlights expects the filament of the bulb to be in a very specific spot, but LED headlights often have a much wider area where the light emits from than the little filament that traditional headlights do. So when installed in cars that aren’t designed for LEDs, the beam pattern can be off and make the light shine at people instead of down toward the road.





  • Make sure you’re buying 14/2 or 12/2 that has a ground wire and running that back to the breaker box. I saw the job you did with the big cable in the floor and it didn’t look like you ran a new cable that had a ground wire. It’s best to replace the old shoddy stuff with circuits that are up to code, even if you’re doing it DIY and your area doesn’t require homeowners to get it inspected. The codes are designed to prevent fires and loss of life.




  • Since you went with 10/2 for a 240v outlet that means your cable will have two hots and a single ground. But the cable you bought will have a black, white and bare/green wire. Make sure that you wrap both ends of the white conductor with red electrical tape to indicate that it is also a hot wire. White normally indicates a neutral, but since you won’t have a neutral wire in this cable, it’s important to mark it. Otherwise someone else may work on this outlet in the future, see a white wire, assume it’s a neutral, wire something up with it as a neutral, and give themselves a pretty bad shock.


  • If you’re in North America, which I assume you are based on the 120v wires, then your assumption about 240v power is a bit off. Both wires can be a hot (120v) wire, 180° out of phase from each other, so they add to 240v. In this case, a neutral wire isn’t necessary to carry the current back, the other hot wire does that. A neutral wire may be used, but then there would be 4 wires.

    The ground wire and the neutral wire actually connect to each other in the panel, but it’s not safe to use a ground wire in place of a neutral, so definitely don’t wire it to the neutral on the outlet.

    If you are unsure of what’s going on with this set of wires, you should really call an electrician to help. Wiring a standard 120v outlet is something a homeowner can do, but identifying an old 240v cable on a dubious circuit is definitely something a qualified electrician should do.





  • There are three separate things going on.

    1. Gamers Nexus made a video exposing LTT for their lack of quality control in their videos regarding providing accurate information after a video where an LTT employee said that they did things better than Gamers Nexus.

    2. Gamers Nexus also brought to light a situation where Billet Labs loaned LTT their prototype liquid cooling block. LTT proceeded to publish a video where they tested it on hardware that it was explicitly not designed for and then proceeded to give it a bad review. In the video, it was clear that LTT knew it was the wrong hardware but Linus specifically said to not waste time on doing it right. After that, they failed to return the prototype and instead they sold it at auction during LTX.

    3. Ex-employee Madison made some pretty serious accusations of sexual harassment and a culture of not taking issues like that seriously. There have been a few “insider sources” that have confirmed her story, though I don’t think we know who they are yet. Nobody has mentioned who the harassment came from yet.